Skip to main content

Specifications

Sensors​

SensorMeasurement rangeAccuracy
pHpH 2.5 - 11+-0.15 pH
EC0.0 - 4.0 mS/cm+-0.15 mS/cm up to 2.0 mS/cm, +-0.3 mS/cm above 2.0 mS/cm
Water level30 - 1800 mm+-1.5 mm
Water temperature0 - 65 °C+-0.75 °C
Air temperature0 - 65 °C+-0.75 °C
Humidity0 - 100 %RH+-3 %RH

Pumps​

Pump typeFlow rateDosing accuracyDosing rangeHead
Peristaltic100 ml/minTBA> 5 ml3 m
Centrifugal4 l/min+-10 %> 0.5 L3 m

Environmental protection​

ComponentRating
Control unitNot protected against water ingress. Must not be mounted in direct sunlight. 0 - 50 °C, below 85 %RH.
Submersible sensorspH, EC, water level and water temperature sensors are intended for continuous submersion in the measured solution.
Centrifugal pumpsIntended for continuous submersion in the pumped solution.
Peristaltic pumpsNot protected against water ingress. Must not be mounted in direct sunlight. 0 - 45 °C, below 85 %RH.

Connectivity​

Wi-Fi, 2.4 GHz only. The device does not join 5 GHz networks.

Power supply​

12 V DC with positive center pin. Maximum current supply capacity must be 1 +- 0.05 A.